Universal Oven UN160plus

The universally applicable lab oven U is Memmert’s classic appliance for temperature control in science, research and material tests in the industry. The technologically perfected masterpiece made of high-quality, hygienic, easy-to-clean stainless steel leaves nothing to be desired in terms of ventilation and control technology, overtemperature protection and precisely tuned heating technology.

Contact us for customization options and pricing. 

Features

Stainless Steel Scratch resistant, hygienic and durable.
AtmoCONTROL Create & monitor programs.
3 Year Warranty A limited 3 year warranty is included with the option to purchase an extra year.
TwinDISPLAY Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.

Temperature & Humidity

Control technology

Safety, Standards, & Data

Interior & Exterior

Accessories

Temperature & Humidity

Temperature Specs:

  • Temperature: 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • Set temperature range: min. 5°C above ambient up to +300°C
  • Resolution of display for setpoint values 0.1°C up to 99.9°C, 0.5°C from 100°C and for actual values
    0.1°C (LED)

Control technology

Control Technology:

  • ControlCOCKPIT: adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays
  • Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Adjustable Parameters: temperature (Celsius or Fahrenheit), air flap position, program time, time zones, daylight savings time
  • Function SetpointWAIT: the process time does not start until the set temperature is reached
  • Language Setting: German, English, Spanish, and French
  • Calibration: three freely selectable temperature values

Safety & Standards

Safety:

  • Temperature control: Overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature
  • AutoSAFETY: additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint
    value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off
    in case of overtemperature
  • Auto diagnostic system: for fault analysis

Additional data

Electrical data

230 Volts
  • (+ / - 10%)
  • 50/60 Hz / 13.9 amps
115 Volts
  • (+ / - 10%)
  • 50/60 Hz / 19.1 amps

Certifications

CE Mark of European Economic Area VDE certified Geprufte Sicherheit certified CUL Certified EAC Certified

Interior & Exterior

Stainless Steel Interior:

  • Volume Approx: 5.9 ft³ / 161 L
  • Width: 22.0 in / 560 mm
  • Height: 28.3 in / 720 mm
  • Depth: 15.7 in / 400 mm
  • Number of Stainless Steel Grids (Standard Equipment): 2
  • Maximum Number of Grids: 8
  • Maximum Loading per Grid: 66 lb / 30 kg
  • Maximum Loading of Chamber: 463 lb / 210 kg

Stainless Steel

For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.

Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.

Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.

For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).

Accessories

 

Model sizes3055751101602604507501060
Stainless steel grids, electropolished E28884 E20164 E20164 E20165 E20165 E28891 E20182 E20182 B41251
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber - - - E29767 E29767 E29766 B32190 B32190 B32550
Perforated stainless steel shelf B29727 B03916 B03916 B00325 B00325 B29725 B00328 B00328 -
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber - - - - - - B32191 B32191 B32549
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02070 E02072 E02072 E02073 E02073 E29726 E02075 E02075 B32599
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 - - - - - - B32763 B32763 -
Max. loading per slide-in drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04356 B04358 B04358 B04359 B04359 B29722 B04362 B04362 B29769
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 - - - - - - B34055 B34055 -
Max. loading per bottom drip tray (kg) 1,5 1,5 1,5 3 3 4 8 8 8
Wall bracket for wall mounting B29755 B29756 B29757 B29758 B29759 - - - -
Guarantee extension by 1 year GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA1Q5 GA2Q5 GA2Q5 GA2Q5 GA2Q5
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172 B33172 B33172 B33172 B33172 B33172 B33172 B33172 B33172
Set of height adjustable feet (4 pcs) B29768 B29768 B29768 B29768 B29768 B29768 B29768 - -
Stacking set (4 pcs) for stacking of appliances of same size B29744 B29744 B29744 B29744 - - - - -
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), straight, for exhaust air ducting (if necessary for connection by hose) B29718 B29718 B29718 B29718 B29718 B29718 B29718 B29718 B29718
Plug-in tube extension (outer diam. 60,3 mm, inner 57 mm), angled, for exhaust air ducting (if necessary for connection by hose), only models U, I, S B29719 B29719 B29719 B29719 B29719 B29719 B29719 B29719 B29719
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29728 B29730 B29732 B29734 B29736 B29738 B29740 B29742 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29729 B29731 B29733 B29735 B29737 B29739 B29741 B29743 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29745 B29747 B29747 B29749 B29749 B29751 B29753 - -
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29746 B29748 B29748 B29750 B29750 - - - -
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33657 B33659 B33659 B33661 B33661 B33664 - - -
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00125 D00127 D00127 D00127 D00127 D00127 D00127 D00127 D00127
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 9 measuring points (size 30), 27 measuring points (sizes 55-1060) to DIN 12880: 2007-05 (plus travel costs, not subject to discount, only GER, A, FR) DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A
Individual on-site Performance Qualification (PQ) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance UIS - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00311 S00311 S00311 S00311 S00311 S00311 S00311 S00311 S00311
Maintenance contract UIS - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00311J S00311J S00311J S00311J S00311J S00311J S00311J S00311J S00311J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205
Calibration of an additional temperature value (not subject to discount) S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215

 

VERSATILE PRODUCTS TO SERVE DEMANDING APPLICATIONS

Medical

Industrial

Electronics

Aerospace

Education

Life Science

Pharmaceuticals

Food & Beverage

Companies Served

atmocontrol instagram pdf techsupport touch twindisplay twitter phone email youtube linkedin play stainless facebook warranty mappin operation