Please enable javascript for full website functionality.

HPP260eco Memmert Constant Climate Chambers

Former Models: HPP260

Overview

HPP 260 Memmert constant climate chambers guarantee the perfect atmosphere for climate and temperature tests. Our HPP260 constant climate chamber is quiet, space-saving, environmentally friendly, and extremely economical. Let us help you build the perfect environmental test chamber.

Contact us for customization options and pricing.

Features

Stainless Steel Scratch resistant, hygienic and durable.
AtmoCONTROL Create & monitor programs.
3 Year Warranty A limited 3 year warranty is included with the option to purchase an extra year.
TwinDISPLAY Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.

Temperature & Humidity

Control technology

Safety, Standards, & Data

Interior & Exterior

Accessories

Temperature & Humidity

Temperature Specs:

  • Setting temperature range:
    without light, with humidity: +5 to +70 °C; with light, with humidity: +5 to +70 °C; with light, without humditiy: 0 to +70 °C; without light, without humidity: 0 to +70 °C
  • Working temperature range: 
    with light, without or with humidity: 15 to +40 °C; without light, with humidity: +5 (at least 20 below ambient temperature) to +70 °C; without light, without humidity: 0 (at least 20 below ambient temperature) to +70 °C
  • Setting accuracy temperature: 
    0.1°C
  • Temperature sensor:
    2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value

Humidity Specs:

  • Setting range humidity:
    10 – 90 % rh
  • Setting accuracy humidity:
    0.5%
  • Humidity:
    humidity supply with distilled water from external tank by self-priming pump
  • Humidification & Dehumidification:
    humidification by hot steam generator; dehumidification by cold trap using the Peltier technology

Heating Concept:

  • Peltier:
    energy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)

Control technology

Control Technology:

  • ControlCOCKPIT:
    TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
  • Language Setting:
    German, English, Spanish, French, Polish, Czech, Hungarian
  • Adjustable Parameters:
    Temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime
  • Timer: 
    Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
  • Function HeatBALANCE: 
    Adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
  • Function SetpointWAIT: 
    The process time does not start until the set temperature is reached
  • Calibration: 
    Three freely selectable values each, 2-point calibration for humidity: 20 and 90 % rh

Safety & Standards

Safety:

  • Temperature control:
    Over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
  • AutoSAFETY: 
    additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature
  • Autodiagnostic system: 
    integral fault diagnostics for temperature and humidity control
  • Alarm:
    with visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank

Additional data

Electrical data

115 Volts
  • 50/60 Hz /approx. 700 W
230 Volts
  • 50/60 Hz / approx. 700 W

Certifications

CE Mark of European Economic Area EAC CertifiedVDE certifiedCUL Certified

Interior & Exterior

Stainless Steel Interior

  • Volume:
    256 l
  • Dimensions W x H x D in mm
    w(A) x h(B) x d(C): 640 x 800 x 500 mm
  • Max. number of internals: 
    9
  • Max. loading of chamber: 
    200 kgs
  • Max. loading per internal: 
    20 kgs

Textured Stainless Steel Casing

  • Dimensions: 
    w x h x d : 745 x 864 x 674 mm
  • Housing: 
    rear zinc-plated steel

Stainless Steel

For many years exterior textured stainless steel has been the unmistakable feature of Memmert ovens, incubators, and climate chambers in laboratory and light-industrial settings. Memmert equipment exemplifies functional design in its most elegant and hygienic form, while still being scratch resistant, robust and durable.

Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and recyclable without question.

Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is undeniable in comparison to others that utilize coated sheet steel, which can corrode very quickly when in constant use.

For the outer housing of all Memmert appliances, textured stainless steel is used (rear walls are zinc-plated sheets). The inner chamber, sliding shelves/grids, housing, interior basin and accessories for every heating bath, stainless steel of class W-St. 1.4301 (ASTM 304) is used. Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless-steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless-steel W-St. 1.4571 (ASTM 316i).

Accessories

 

Model sizes110260410750106014002200
Stainless steel grids, electropolished E20165 E28891 E28891 E20182 B41251 B38955 B38955
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) E29767 E29766 E29766 B32190 B32550 - -
Perforated stainless steel shelves B00325 B29725 B29725 B00328 - - -
Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) - - - B32191 B32549 - -
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02073 E29726 E29726 E02075 B32599 - -
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 - - - B32763 - - -
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359 B29722 B29722 B04362 B29769 - -
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 - - - B34055 - - -
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200. B49092 B49092 - - - - -
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7
Max. loading per slide-in drip tray (kg) 3 4 4 8 8 - -
Max. loading per bottom drip tray (kg) 3 4 4 8 8 - -
Guarantee extension by 1 year GA2Q5 GA3Q5 GA3Q5 GA3Q5 GA4Q5 GA4Q5 GA4Q5
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170
Set of height adjustable feet (4 pcs) B29768 B29768 - - - - -
Stacking set (4 pcs) for stacking of appliances of same size B29744 - - - - - -
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29734 B29738 B42116 B29742 B29742 - -
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29735 B29739 B42117 B29743 B29743 - -
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29749 B29751 - - - - -
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29750 - - - - - -
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33661 B33664 - - - - -
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713 B04713 B04713 B04713 - - -
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714 B04714 B04714 B04714 B04714 B04714 B04714
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) E48847 E48847 E48847 E48847 E48847 E48847 E48847
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) E48848 E48848 E48848 E48848 E48848 E48848 E48848
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00125 D00127 D00127 D00127 D00127 D00127 D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136 D00136 D00136 D00136 D00136 D00136 D00136
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137 D00137 D00137 D00137 - - -
On-site IQ/OQ for a freely selectable temperature and humidity value, including temperature distribution survey for 27 measuring points (sizes 110 - 1060, 2200) and 26 measuring points (size 1400) to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ101 DLQ101 DLQ101 DLQ101 DLQ101 DLQ101 DLQ101
Extension of DLQ101 by an additional freely selectable temperature and humidity value (not subject to discount) DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A DLQ101A
Individual on-site Performance Qualification (PQ) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance HPPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00314 S00314 S00314 S00314 S00314 S00314 S00314
Maintenance contract HPPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00314J S00314J S00314J S00314J S00314J S00314J S00314J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) S00205 S00205 S00205 S00205 S00205 S00205 S00205
Calibration of an additional temperature value (not subject to discount) S00215 S00215 S00215 S00215 S00215 S00215 S00215
Calibration of one freely selectable temperature and humidity value (excluding travel costs, not subject to discount, GER, AT, FR only) S00207 S00207 S00207 S00207 S00207 S00207 S00207
Calibration of an additional temperature and humidity value (not subject to discount) S00216 S00216 S00216 S00216 S00216 S00216 S00216

 

Introducing Peltier App

Redefining Energy Efficiency in Equipment Temperature Control!

Experience Efficiency Now

VERSATILE PRODUCTS TO SERVE DEMANDING APPLICATIONS

Medical

Industrial

Electronics

Aerospace

Education

Life Science

Pharmaceuticals

Food & Beverage

Companies Served

atmocontrol instagram pdf techsupport touch twindisplay twitter phone email youtube linkedin play stainless facebook warranty mappin operation